Prepared For:
Sample Buyer
Property Address:
39 Chickory Lake
Whoville, FL
![]() |
Carl Pennick
10033 Hart Branch Circle
Orlando, FL 32832
877-274-4299
| Date: 11/26/2004 | Time: 1:30 PM | Report ID: sample 2 |
| Property: 39 Chickory Lake Whoville, NC |
Customer: Sample Buyer |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
| Age Of Home: Over 50 Years | Client Is Present: Yes | Radon Test: not performed |
| Water Test: No | Weather: Cloudy | Temperature: Below 60 |
| Rain in last 3 days: Yes |
The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the home inspector or other persons.
![]() |
| Styles & Materials FOUNDATION: MASONRY BLOCK POURED CONCRETE FLOOR STRUCTURE: 2 X 8 2 X 10 WOOD JOISTS WALL STRUCTURE: WOOD MASONRY COLUMNS OR PIERS: MASONRY BLOCK SUPPORTING WALLS CEILING STRUCTURE: 2X6 ROOF STRUCTURE: STICK-BUILT 2 X 8 RAFTERS COMMON BOARD ROOF-TYPE: GABLE |
||||||||||||||||||||||||||||||||||||||||||||||||
![]() 1.5 Picture 1 |
The home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility.
| Styles & Materials SIDING STYLE: CEMENT STUCCO SIDING MATERIAL: STONE MASONRY EXTERIOR ENTRY DOORS: WOOD WINDOW TYPES: SINGLE PANE CASEMENT APPURTENANCE: BALCONY PATIO AUTO OPENER MANUFACTURER: N/A GARAGE DOOR MATERIAL: WOOD GARAGE DOOR TYPE: TWO MANUAL DRIVEWAY: ASPHALT |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() 2.1 Picture 1 |
![]() 2.1 Picture 2 |
![]() 2.4 Picture 1 | ![]() 2.4 Picture 2 |
![]() 2.4 Picture 3 |
![]() 2.5 Picture 1 |
![]() 2.5 Picture 2 | ![]() 2.5 Picture 3 |
![]() 2.5 Picture 4 |
![]() 2.6 Picture 1 | ![]() 2.6 Picture 2 |
The home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing. The home inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors.
| Styles & Materials ROOF COVERING: TILE RUBBER MEMBRANE VIEWED ROOF COVERING FROM: GROUND CHIMNEY (exterior): MASONRY/STUCCO |
||||||||||||||||||||||||||||||||||||
![]() 3.0 Picture 1 |
![]() 3.0 Picture 2 |
![]() 3.0 Picture 3 |
![]() 3.1 Picture 1 |
![]() 3.1 Picture 2 |
![]() 3.3 Picture 1 |
The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials.
| Styles & Materials WATER SOURCE: PUBLIC PLUMBING SUPPLY: NOT VISIBLE PLUMBING DISTRIBUTION: GALVANIZED COPPER POLY WASHER DRAIN SIZE: NOT VISIBLE PLUMBING WASTE: PVC CAST IRON (OLD) WATER HEATER POWER SOURCE: GAS (QUICK RECOVERY) CAPACITY: 50 GAL (2-3 PEOPLE) MANUFACTURER: PENNFIELD |
||||||||||||||||||||||||||||||||||||||||||||||||
![]() 4.1 Picture 1 | ![]() 4.1 Picture 2 |
![]() 4.1 Picture 3 |
![]() 4.3 Picture 1 |
![]() 4.4 Picture 1 |
The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment.
| Styles & Materials ELECTRICAL SERVICE CONDUCTORS: BELOW GROUND ALUMINUM 220 VOLTS PANEL CAPACITY: 200 AMP PANEL TYPE: CIRCUIT BREAKERS BRANCH WIRE 15 and 20 AMP: COPPER WIRING METHODS: ROMEX CONDUIT NOT VISIBLE |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() 5.3 Picture 1 | ![]() 5.3 Picture 2 |
![]() 5.3 Picture 3 |
![]() 5.3 Picture 4 |
No outlet in Hall Bath except for one that is built in light fixture. These outlets are considered unsafe if not grounded and bathroom should have its own duplex GFCI outlet (Ground Fault Circuit Interrupter).
The home inspector shall observe permanently installed heating systems including: Heating equipment; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The home inspector shall describe: Energy source; and Heating equipment and distribution type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms.
| Styles & Materials HEAT TYPE: CIRCULATING BOILER ENERGY SOURCE: OIL NUMBER OF HEAT SYSTEMS (excluding wood): ONE TYPES OF FIREPLACES: NON-VENTED GAS LOGS OPERABLE FIREPLACES: ONE NUMBER OF WOODSTOVES: NONE |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Liner for fireplace or boiler were not inspected by our company. Recommend a qualified chimney sweep inspect for safety.
![]() 6.3 Picture 1 |
The home inspector shall observe: Central air conditioning and permanently installed cooling systems including: Cooling and air handling equipment; and Normal operating controls. Distribution systems including: Fans, pumps, ducts and piping, with associated supports, dampers, insulation, air filters, registers, fan-coil units; and The presence of an installed cooling source in each room. The home inspector shall describe: Energy sources; and Cooling equipment type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance The home inspector is not required to: Observe window air conditioners or operate cooling systems when weather conditions or other circumstances may cause equipment damage; Observe non-central air conditioners; or Observe the uniformity or adequacy of cool-air supply to the various rooms.
| Styles & Materials COOLING EQUIPMENT TYPE: AIR CONDITIONER UNIT COOLING EQUIPMENT ENERGY SOURCE: ELECTRICITY NUMBER OF A/C UNITS: ONE |
||||||||||||||||||||||||||||||||||||
![]() 7.2 Picture 1 |
The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Styles & Materials CEILING MATERIALS: PLASTER WALL MATERIAL: PLASTER FLOOR COVERING(S): CARPET TILE WOOD CABINETRY: WOOD VENEER COUNTERTOP: GRANITE |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() 8.0 Picture 1 |
![]() 8.0 Picture 2 |
![]() 8.1 Picture 1 |
![]() 8.1 Picture 2 |
![]() 8.6 Picture 1 |
The home inspector shall observe: Insulation and vapor retarders in unfinished spaces; Ventilation of attics and foundation areas; Kitchen, bathroom, and laundry venting systems; and the operation of any readily accessible attic ventilation fan, and, when temperature permits, the operation of any readily accessible thermostatic control. The home inspector shall describe: Insulation in unfinished spaces; and Absence of insulation in unfinished space at conditioned surfaces. The home inspector shall: Move insulation where readily visible evidence indicates the need to do so; and Move insulation where chimneys penetrate roofs, where plumbing drain/waste pipes penetrate floors, adjacent to earth filled stoops or porches, and at exterior doors. The home inspector is not required to report on: Concealed insulation and vapor retarders; or Venting equipment that is integral with household appliances.
| Styles & Materials ATTIC INSULATION: BLOWN FIBERGLASS R- VALUE: R-30 OR BETTER VENTILATION: PASSIVE EXHAUST FAN TYPES: NONE DRYER POWER SOURCE: 22O ELECTRIC DRYER VENT: FLEXIBLE METAL PVC RIGID |
||||||||||||||||||||||||||||||||||||
![]() 9.2 Picture 1 |
The home inspector shall observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.
| Styles & Materials DISHWASHER: MAYTAG DISPOSER: KITCHEN AIDE RANGE/OVEN: GENERAL ELECTRIC BUILT-IN MICROWAVE: GENERAL ELECTRIC TRASH COMPACTORS: GENERAL ELECTRIC |
||||||||||||||||||||||||||||||||||||||||||||||||
![]() 10.5 Picture 1 |
![]() HomeBuyers Inspection HBI
18 Business Park Circle |
Customer |
Property Address |
STRUCTURAL COMPONENTS
| 1.0 | FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | |
| Inspected | ||
|
Crawlspace is limited in access due to plumbing pipes and was not inspected by my company. |
||
| 2.0 | WALL CLADDING FLASHING AND TRIM | |
| Repair or Replace | ||
|
Stucco over-all appears good except for some areas peeling where obvious. For example on rear of home around balcony porch at rear and at chimney. |
||
| 2.1 | DOORS (Exterior) | |
| Repair or Replace | ||
|
Entry door at rear of home deteriorated at bottom of jamb(s). A repair or replacement is needed. Recommend repair or replace as needed using a qualified person. |
||
| 2.1 | DOORS (Exterior) | |
| Repair or Replace | ||
|
Entry door to rear balcony is deteriorated at bottom. A repair or replacement is needed. Recommend repair or replace as needed using a qualified person. |
||
| 2.3 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) | |
| Not Present | ||
|
The Two door Garage at rear of home appears narrow and may not allow large cars to enter. |
||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | |
| Repair or Replace | ||
|
The balcony in rear has loose or missing stucco and water intrusion is occurring through concrete wall. Repairs are needed. Recommend a qualified mason perform the work. |
||
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) | |
| Repair or Replace | ||
|
Ground Drain located at rear of home at basement/garage entry will need periodical cleaning and maintenance. I am unable to determine if water will over-run or by-pass drain even if kept clean under certain weather conditions. |
||
| 2.6 | EAVES, SOFFITS AND FASCIAS | |
| Repair or Replace | ||
|
Wood fascia at eave on rear of home are weathered and deteriorated. Repairs can involve removal of guttering to replace fascia board. Photo shows blackened fascia with white mold on kitchen side of rear. Paint is peeling on front of home at wood trim or fascia that may include deterioration. Recommend a qualified contractor inspect and repair as needed. |
||
| 3.0 | ROOF COVERINGS | |
| Not Inspected | ||
|
Due to the fact that this home has a tile roof, I am not qualified to inspect this roof in a way that is considered thorough. Tile roofs can leak and not show an obvious cause during a routine inspection. A separate inspection by a qualified roofing contractor who specializes in tile roof replacement should inspect this roof before you purchase. Tile roofs can be expensive to repair or replace. |
||
| 3.0 | ROOF COVERINGS | |
| Not Inspected | ||
|
EPDM rubber membrane roof on balcony above kitchen appears unfinished with plastic draped in areas and according to the sellers comments. I strongly recommend a warranty request from the roofing contractor performing this work. The damage to the kitchen ceiling from this leak is noted in the Interiors section. I did not inspect cavity between joists for possible existence of mold that can be caused by a leak. |
||
| 3.0 | ROOF COVERINGS | |
| Not Inspected | ||
|
Roof tile is cracked above front porch. Other cracks, imperfections in installation or performance may exist on roof of home. |
||
| 3.1 | FLASHINGS | |
| Repair or Replace | ||
|
Leak sign in attic near chimney of Living room. See roof covering notes. |
||
| 3.1 | FLASHINGS | |
| Repair or Replace | ||
|
Flashing edge is laid flat on side wall or did not tuck into wall and is exposed or may allow water to enter at rear of home on lower roof. Other areas may exist and was not inspected by my company. See roofing notes. |
||
| 4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
| Inspected | ||
|
Polybutylene plastic plumbing supply lines (PB) are installed in the subject house. Polybutylene has been used in this area for many years, but has had a higher than normal failure rate, and is no longer being widely used. Copper and Brass fittings used in later years have apparently reduced the failure rate. This subject house has copper fittings. For further details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com |
||
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
| Repair or Replace | ||
|
"Three-prong" outlet is not grounded. Needs correcting in Bedroom at end of hall in back room. Also outlet cover is damaged at middle bedroom. Electrical issues are considered a hazard until repaired. Recommend repair as needed. |
||
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
| Repair or Replace | ||
|
Outlet in middle bedroom is old and the shape of recepticle is out dated and can no longer be used with standard plugs. |
||
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
| Repair or Replace | ||
|
Doorbell is missing. |
||
| 5.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) | |
| Repair or Replace | ||
|
No outlet found in hall bath. Recommend a duplex GFCI outlet be installed by a licensed electrician. No outlet in Hall Bath except for one that is built in light fixture. These outlets are considered unsafe if not grounded and bathroom should have its own duplex GFCI outlet (Ground Fault Circuit Interrupter). |
||
| 6.3 | CHIMNEYS, FLUES AND VENTS | |
| Not Inspected | ||
|
Vent pipe for oil fired boiler needs mastic sealed around pipe where it enters chimney. This is a safety issue and should be repaired. Recommend a qualified licensed heat contractor inspect further and repair as needed. Liner for fireplace or boiler were not inspected by our company. Recommend a qualified chimney sweep inspect for safety. |
||
| 7.2 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
| Repair or Replace | ||
|
Disposable filters is dirty. Clogged filters can raise energy bill and shorten life span of compressor. Recommend repair or replace as needed using a qualified person. |
||
| 7.3 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM | |
| Inspected | ||
|
Cooling equipment serves the upstairs of home only. The main level has no cooling source (FYI). |
||
| 8.1 | WALLS | |
| Repair or Replace | ||
|
Bubble in paint or plaster coating indicates moisture has affected it either by wall or window. Recommend search for a possible cause and repair as needed to prevent possible further damage over extended period. |
||
| 8.1 | WALLS | |
| Repair or Replace | ||
|
Water intrusion signs in basement/garage and wood deterioration at bathroom stall is present. Water intrusion may be from ground drain in front of door becoming clogged or drain may not be adequate in certain weather conditions. Repair as desired. |
||
| 8.6 | WINDOWS (REPRESENTATIVE NUMBER) | |
| Inspected | ||
|
Some glass is cracked in windows of home. Cracked glass can cause air infiltration or may cause an injury. Recommend repair as needed using a qualified contractor. |
||
| 9.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) | |
| Inspected | ||
|
Floor system is not insulated. Heat loss can occur more on this home than one that is properly insulated. |
||
| 9.2 | VENTING SYSTEMS (Kitchens, baths and laundry) | |
| Inspected | ||
|
Dryer vent piping turns up before exiting home and may require periodical cleaning. |
||
| 10.5 | MICROWAVE COOKING EQUIPMENT | |
| Inspected | ||
|
Recommend checking with manufacturer of microwave for clearance requirements between range top and microwave as a precaution. This unit appears lower than normal. |
||
Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To HG
1.0 Picture 1